Jufu Water Technology Co., Ltd

Water Treatment Equipment Expert Worldwide!

Manufacturer from China
Active Member
3 Years
Home / Products / RO Water Treatment System /

2.2KW Reverse Osmosis Water Filter System Ro Water Treatment Plant

Contact Now
Jufu Water Technology Co., Ltd
Province/State:Shaanxi
Country/Region:china
Contact Person:MsChloe Cheung
Contact Now

2.2KW Reverse Osmosis Water Filter System Ro Water Treatment Plant

Ask Latest Price
Video Channel
Brand Name :Jufu
Model Number :JFRO-1000L
Certification :ISO9001
Place of Origin :China
MOQ :1 unit
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :2-4 weeks
Packaging Details :Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping.
Host Size :1000x600x1600mm (can be customized)
Power :2.2KW
Power Supply :220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure :0.8-1.2MPa
Designed Water Inlet :2000L/h
Outlet Flow :1000L/h
Desalination rate :≥99.5%
Raw Water Pump :CNP/NYP/GRUNDFOS (Optional)
Membrane size :4040
Number of Membranes :4
Membrane elements :DOW/Hydranautics/Troy/Vontron (optional)
Control valve :Manual/Automatic
Control Valve Brand :FLECK/RUNXIN
Tank Material :SS/FRP (Optional)
Pipe Material :U-PVC, Stainless steel (Optional)
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Ro Water Treatment Plant Reverse Osmosis Water Filter System Ro Water System

Product Introduction of RO Water Treatment System
There are many pores on the reverse osmosis semi-permeable membrane, and the size of these pores is equivalent to the size of water molecules. Since bacteria, viruses, most organic pollutants and hydrated ions are much larger than water molecules, they cannot pass through the reverse osmosis semi-permeable membrane. The membrane is separated from the water phase passing through the reverse osmosis membrane. Among the many impurities in water, soluble salts are the most difficult to remove. Therefore, the water purification effect of reverse osmosis is often determined according to the desalination rate. The desalination rate of reverse osmosis is mainly determined by the reverse osmosis semi-permeable membrane selectivity. The salt removal rate of the reverse osmosis membrane element with higher selectivity can be as high as 99.7%.

The Basic Working Principle of RO Water Treatment System
1:Pre-treatment system
It mainly includes: raw water pump, quartz sand filter, dosing device, security filter, precision filter. Its main function is to reduce the pollution index of raw water and other impurities such as residual chlorine, so as to meet the water inlet requirements of reverse osmosis. The equipment configuration of the pretreatment system should be determined according to the specific conditions of the raw water.
2:Reverse Osmosis system
It mainly includes multi-stage high-pressure pumps, reverse osmosis membrane elements, membrane casings (pressure vessels), pressure instruments, flow meters, brackets, etc. Its main function is to remove impurities in the water and make the effluent meet the requirements of use. According to water requirements, a single-stage reverse osmosis device or a double-stage reverse osmosis device can be used.
RO membrane group

Technical Specifications of RO Water Treatment System

1000LPH Reverse Osmosis System
ModelJFRO-1000L
Host Size

1000x600x1600mm (can be customized)

Power2.2KW
Power Supply

220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized

Operating Pressure0.8-1.2MPa
Recovery Rate50%
Designed Water Inlet2000L/h
Outlet Flow1000L/h
Desalination Rate≥99.5%
RO FrameSUS304
Membrane Size4040
Membrane ElementsDOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes4
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Raw Water PumpCNP/NYP/GRUNDFOS (Optional)
Tank MaterialSS/FRP (Optional)
Control ValveManual/Automatic
Control Valve BrandFLECK/RUNXIN
Membrane HousingSS/FRP (Optional)
Pipe MaterialU-PVC, Stainless steel (Optional)


























Advantages of RO water treatment system:
Reverse osmosis equipment belongs to physical desalting method, which has many advantages.
1) Non-phase-change physical method was used to desalinate and purify the saline water under norma temperature.
2) Desalting rate of single membrane element is 99.3% and can remove colloid, organics, bacteria, virus and all kinds of heavy metals in water at the same time.
3) With water pressure as the driving force, energy consumption is the lowest among many treatment methods.
4) No need for large amount of chemical treatment, no elimination of chemical waste liquid, no environmental pollution, and the recovery rate is over 70%.
5) High automation program, automatic stop in case of ailure, with automatic protection function.
6) The system is simple, easy to operate, and the water quality is stable.
7) Equipment covers small area, compact structure, reliable operation and high water quality.

Process flow of RO Water Treatment System
Raw water → Raw water tank → Raw water pump → Multi-media filter (quartz sand filter) → Activated carbon filter → Soft water processor → Precision filter → High pressure pump → Primary reverse osmosis (RO) device → Purified water tank → High pressure pump → Two Stage reverse osmosis → ultraviolet sterilization device → water point.

2.2KW Reverse Osmosis Water Filter System Ro Water Treatment Plant

Photos of Reverse Osmosis Water Treatment System
2.2KW Reverse Osmosis Water Filter System Ro Water Treatment Plant
2.2KW Reverse Osmosis Water Filter System Ro Water Treatment Plant

2.2KW Reverse Osmosis Water Filter System Ro Water Treatment Plant

2.2KW Reverse Osmosis Water Filter System Ro Water Treatment Plant
2.2KW Reverse Osmosis Water Filter System Ro Water Treatment Plant

2.2KW Reverse Osmosis Water Filter System Ro Water Treatment Plant

2.2KW Reverse Osmosis Water Filter System Ro Water Treatment Plant

2.2KW Reverse Osmosis Water Filter System Ro Water Treatment Plant

2.2KW Reverse Osmosis Water Filter System Ro Water Treatment Plant
2.2KW Reverse Osmosis Water Filter System Ro Water Treatment Plant

FAQ:

1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)

Model 4040 is designed by 0.25m3/h

Model 8040 is designed by 1-1.2m3/h

2. What is the material of mechanical filter?

Carbon steel, stainless steel, fiberglass

3.What are the multi-way control valves?

Manual control valve, automatic control valve

Multi - way control valve is divided into: filter valve and softening valve

Automatic control valve is divided into: time type and flow type.

Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.














































































Inquiry Cart 0