Add to Cart
One Stage 1PH Water Purification Equipment RO Water Treatment System For Well Water
Types of common problems in reverse osmosis system operation:
1. Pretreatment dosing problem
2. The intake SDI exceeds the threshold
3. Low removal rate of organic matter
4. Design problems of sand filter
5. Water toner from activated carbon filter
6. Backwash system design problems
7. Short cycle of security filter element
8. Scale inhibitor selection problem
9. RO water yield drops rapidly
The instrument (sensor) parameters of the water treatment system must be calibrated every 3-6 months to ensure the accuracy of equipment parameters. Because of the difference of surface water sources, the types of operating problems of reverse osmosis equipment are not the same in different places. Therefore, users should carefully analyze the running status of their own system. Especially in the characteristics of membrane pollution and system cleaning should be explored according to the actual situation to find out the solution to the problem suitable for the system.
For the outage protection process of reverse osmosis system, if conditions exist, it is recommended to adopt a suitable way for long-term protection. Avoid physical damage of reverse osmosis membrane caused by frequent start-stop under short-term protection or low pressure flushing conditions.
RO Water Treatment System Specification
Model | JFRO-1000L |
Host Size | 1000x600x1600mm (can be customized) |
Power | 2.2KW |
Power Supply | 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized |
Operating Pressure | 0.8-1.2MPa |
Recovery Rate | 50% |
Designed Water Inlet | 2000L/h |
Outlet Flow | 1000L/h |
Desalination Rate | ≥99.5% |
RO Frame | SUS304 |
Membrane Size | 4040 |
Membrane Elements | DOW /Hydranautics/Troy/ Vontron (Optional) |
Number of Membranes | 4 |
Raw Water Pump | CNP/NYP/GRUNDFOS (Optional) |
High Pressure Pump | CNP/NYP/GRUNDFOS (Optional) |
Tank Material | SS/FRP(Optional) |
Control Valve | Manual/Automatic |
Control Valve Brand | FLECK/RUNXIN |
Membrane Housing | SS/FRP |
Pipe Material | U-PVC/ Stainless steel (Optional) |
Flow Chart of RO Water Treatment System
Raw water pump → mechanical filter → activated carbon filter → Sodium ion exchanger → precision filter → high pressure pump → reverse osmosis → ozone sterilizer (UV)
Unique Characteristics of RO Water Treatment System
1. The single-membrane desalination rate can reach 99%, the desalination rate of the primary reverse osmosis system can generally be stabilized above 90%, and the desalination rate of the secondary reverse osmosis system can generally be stabilized above 98%.
2. Because the reverse osmosis equipment can effectively remove microorganisms, organic substances and inorganic substances such as iron and silicon, the quality of the effluent is higher than other methods.
3. The equipment has small footprint, compact structure, reliable operation and convenient operation.
4. The system is simple, the degree of automation is high, the fault is automatically shut down, and it has the function of automatic protection.
5. The recovery rate can reach more than 70%.
6. Save the chemical consumption cost, labor cost and waste water treatment cost generated by regeneration, and reduce environmental pollution.
Application of RO Water Treatment System
1, seawater desalination, brackish water desalination
2, industrial pure water, boiler supply water manufacturing
3, drinking water municipal water supply, drainage, water treatment
4, cooling circulating water, industrial, municipal sewage treatment
5, food, pharmaceutical and various processes of water, semiconductor ultrapure water manufacturing
6. Desalination of various aqueous solutions
7, surface water turbidity removal, wastewater treatment and decolorization
8. Municipal landscape and agricultural irrigation
9. Separation, concentration, separation and concentration of dairy products
Photos of RO Water Treatment System
Here's a guide to getting the best offer
1. What is the source water to be treated? Industrial wastewater, tap water, well water, groundwater or seawater? Is there a water quality analysis report for conductivity?
2. How much capacity water treatment system do you need? 1000 liters per hour, 5000 liters per hour or more?
3. What is the purpose of outputting purified water? Drinking water, food, beverage manufacturing, industrial use or medical production use?
FAQ:
1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)
Model 4040 is designed by 0.25m3/h
Model 8040 is designed by 1-1.2m3/h
2. What is the material of mechanical filter?
Carbon steel, stainless steel, fiberglass
3, what are the multi-way control valves?
Manual control valve, automatic control valve
Multi - way control valve is divided into: filter valve and softening valve
Automatic control valve is divided into: time type and flow type.
Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.