Host Size :2700x600x1600mm (can be customized)
Power :3KW
Power Supply :220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure :0.8-1.2MPa
Designed Water Inlet :3000L/h
Outlet Flow :2000L/h
Desalination rate :≥99.5%
Raw Water Pump :CNP/NYP/GRUNDFOS (Optional)
Membrane size :4040
Number of Membranes :8
Membrane elements :DOW/Hydranautics/Troy/Vontron (optional)
Control valve :Manual/Automatic
Control Valve Brand :FLECK/RUNXIN
Tank Material :SS/FRP (Optional)
Pipe Material :U-PVC, Stainless steel (Optional)
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

2TPH RO Water Treatment System FRP Reverse Osmosis Nitrate Removal Plant

Reverse osmosis preparation principle:


The reverse osmosis water treatment equipment is usually composed of raw water pretreatment system, reverse osmosis purification system and ultra-purified post-treatment system. The main purpose of pretreatment is to make the raw water meet the water intake requirements of the reverse osmosis membrane separation components and ensure the stable operation of the reverse osmosis purification system. Reverse osmosis membrane system is the most economical and efficient purification method to remove more than 98% ions, organic matter and 100% microorganisms in raw water (theoretically).

Technical Specifications of RO Water Treatment System

2000LPH Reverse Osmosis System
Model JFRO-2000L
Host Size 2700x600x1600mm (can be customized)
Power 3KW
Power Supply 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure 0.8-1.2MPa
Recovery Rate 67%
Designed Water Inlet 3000L/h
Outlet Flow 2000L/h
Desalination Rate ≥99.5%
RO Frame SUS304
Membrane Size 4040
Membrane Elements DOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes 8
Raw Water Pump CNP/NYP/GRUNDFOS (Optional)
High Pressure Pump CNP/NYP/GRUNDFOS (Optional)
Tank Material SS/FRP(Optional)
Control Valve Manual/Automatic
Control Valve Brand FLECK/RUNXIN
Membrane Housing SS/FRP
Number of Membrane housing 4
Pipe Material U-PVC/ Stainless steel (Optional)

Reverse osmosis working principle:


Reverse osmosis is the most precise membrane liquid separation technology. The operating pressure on the inlet (concentrated solution) side is applied to overcome the natural osmotic pressure. When the operating pressure higher than the natural osmotic pressure is added to the concentrated solution side, the flow direction of the natural osmosis of water molecules will be reversed. Reverse osmosis equipment can block all soluble salt and molecular weight greater than 100 organic matter, but allow water molecules through, reverse osmosis composite membrane desalination rate is generally greater than 98%, they are widely used in industrial pure water and electronic ultrapure water preparation, drinking water production, boiler feed water and other processes, the use of reverse osmosis equipment before ion exchange can be significantly reduced operating water and wastewater emissions.

Process flow of RO Water Treatment System
Raw water pump→ mechanical filter(quartz sand filter)→ activated carbon filter→ Water softener filter→security filter→ high pressure pump →reverse osmosis system

2TPH RO Water Treatment System FRP Reverse Osmosis Nitrate Removal Plant

Photos of reverse osmosis water treatment system
2TPH RO Water Treatment System FRP Reverse Osmosis Nitrate Removal Plant

2TPH RO Water Treatment System FRP Reverse Osmosis Nitrate Removal Plant

2TPH RO Water Treatment System FRP Reverse Osmosis Nitrate Removal Plant

2TPH RO Water Treatment System FRP Reverse Osmosis Nitrate Removal Plant

2TPH RO Water Treatment System FRP Reverse Osmosis Nitrate Removal Plant

2TPH RO Water Treatment System FRP Reverse Osmosis Nitrate Removal Plant

2TPH RO Water Treatment System FRP Reverse Osmosis Nitrate Removal Plant

2TPH RO Water Treatment System FRP Reverse Osmosis Nitrate Removal Plant

FAQ:

1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)

Model 4040 is designed by 0.25m3/h

Model 8040 is designed by 1-1.2m3/h

2. What is the material of mechanical filter?

Carbon steel, stainless steel, fiberglass

3.What are the multi-way control valves?

Manual control valve, automatic control valve

Multi - way control valve is divided into: filter valve and softening valve

Automatic control valve is divided into: time type and flow type.

Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.

Inquiry Cart 0