Jufu Water Technology Co., Ltd

Water Treatment Equipment Expert Worldwide!

Manufacturer from China
Active Member
3 Years
Home / Products / Brackish Water Desalination System /

Agriculture Brackish Water RO System Salt Removal Water Softener

Contact Now
Jufu Water Technology Co., Ltd
Province/State:Shaanxi
Country/Region:china
Contact Person:MsChloe Cheung
Contact Now

Agriculture Brackish Water RO System Salt Removal Water Softener

Ask Latest Price
Brand Name :Jufu
Model Number :JFRO
Certification :ISO9001
Place of Origin :China
MOQ :1 Set
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :2-4 Weeks
Packaging Details :Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping.
Item :Brackish Water Desalination System
Raw Water :Well Water, Underground Water, Brackish Water...
Desalination Rate :≥99.5%
Power Supply :220V /380V/460V - 50Hz/60Hz
Function :Remove TDS/TSS All Kinds Of Impurities
Tank material :SS/FRP (optional)
Ro membrane :Dow/Toray/Hydraunics/ Vontron...
Valve :Automatic / Manual
Warranty :1 Year
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Brackish Water RO System Salt Removal Water Softener For Agriculture

RO System & Barckish Water Desalination System

Reverse osmosis (RO) is a water purification technology that uses semi-permeable membranes to remove ions, molecules and larger particles from drinking water, resulting in purified water.
The brackish water desalination device is a water treatment device that combines the principles of reverse osmosis technology and micro-computer technology and mechatronics technology. The desalination of brackish water is actually the desalination of salt water, so that the salt water is desalinated or desalinated or reaches the drinking water standard after treatment.Can be personalized according to the actual needs of users, using more advanced back pressure technology, can save users a lot of operating costs and equipment technical costs.

RO Water Treatment Plant Consumables Replacement Cycle

ConsumablesPerformance Life Span
1Quartz sand3 years
2Activated carbon3 years
3Water softening resin1 years
4PP filter6 months
5RO membrane24 months
6UV lamp1 years

















Working Process of Brackish Water Desalination System

Agriculture Brackish Water RO System Salt Removal Water Softener

Function of Each Part of Brackish Water Desalination System

1. Feed water pump pump-- provide the pressure to quartz sand filter/active carbon filter;
2. Multi-medium filter-- get rid of turbidity, suspended matter, organic matter, colloid, ect.;
3. Active Carbon filter--Remove the color, free chloride, organic matter, harmful matter, ect.;
4. Softener--exchange "ions" of calcium and magnesium with the most common and easiest method;
5. Security filter--prevent large particles, bacteria, viruses into RO membrane, accuracy is 5um;
6. High pressure pump-- Provide the high pressure to RO membrane;
7. Brackish water treatment system-- main part of the plant. The RO membrane's desalting rate can reach 99%, removing over 99% ions.


Safe Operation of Brackish Water Desalination System

Although the operation of the RO system has proven reliable, there may still be some reports of malfunctions. For example, improper pretreatment of feed water, various operating parameters are not controlled according to regulations, etc. Therefore, the reverse operation of the reverse osmosis desalination system must pay attention to the following issues:
1. Regularly test SDI index. Excessive SDI will cause irreversible contamination of the membrane module and shorten the service life of the module.
2. Control the recovery rate. The recovery rate is too high. On the one hand, the component of insoluble salt is more than the solubility product, forming scale. On the other hand, if the flow rate of concentrated water in the module is too low, it is easy to cause concentration polarization and cause scaling, which is not conducive to the discharge of colloids and suspended solids in the water.
3. Pay attention to the pressure difference of the membrane module. The initial differential pressure of the membrane module is small. If the differential pressure increases rapidly, the membrane module is contaminated or fouled, and the cause must be identified and corrected.
4. Pay attention to changes in water production and desalination rate, which usually occur at the same time as changes in pressure difference. If the water production and desalination rate change significantly in a short period of time, it is necessary to check whether the pretreatment system is operating normally, such as whether the dosage is appropriate, whether the filter is leaking and so on.


Jufu's Service

Our commitment is to promptly and accurately respond to customer requirements, to be honest and trustworthy to customers, to serve you thoughtfully, and to continuously improve service quality. Our company will continue to develop, expand knowledge, keep improving, and improve ourselves. Your satisfaction is the goal and direction of our work.
Our commitment is to respond to customers' request in atimely and accurate manner, honest and thrustworthy to customers, and considerate to serve you, constantly improve service quality. Our company will continue to develop, expand knowledge, profocoent in business, improve themselves, your satisfaction is the goal and direction of our work.



Agriculture Brackish Water RO System Salt Removal Water Softener


Agriculture Brackish Water RO System Salt Removal Water Softener


Agriculture Brackish Water RO System Salt Removal Water Softener

Agriculture Brackish Water RO System Salt Removal Water Softener


Agriculture Brackish Water RO System Salt Removal Water Softener


Agriculture Brackish Water RO System Salt Removal Water Softener


Agriculture Brackish Water RO System Salt Removal Water Softener


Agriculture Brackish Water RO System Salt Removal Water Softener



































































Inquiry Cart 0