Jufu Water Technology Co., Ltd

Water Treatment Equipment Expert Worldwide!

Manufacturer from China
Active Member
3 Years
Home / Products / Drinking Water Treatment System /

500LPH Drinking Water RO System FRP Manual Control For Pure Water

Contact Now
Jufu Water Technology Co., Ltd
Province/State:Shaanxi
Country/Region:china
Contact Person:MsChloe Cheung
Contact Now

500LPH Drinking Water RO System FRP Manual Control For Pure Water

Ask Latest Price
Brand Name :Jufu
Model Number :JFRO-500L
Certification :ISO9001
Place of Origin :China
MOQ :1 unit
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :2-4 weeks
Packaging Details :Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping.
RO frame :SUS304
Warranty :1 Year
MOQ :1 unit
Tank material :SS/FRP (optional)
Pipe material :U-PVC/Stainless steel (optional)
Desalination rate :≥99.5%
Control valve :Manual/Automatic
Recovery rate :50%
Country of origin :China
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

500LPH Drinking Water RO System FRP Manual Control For Pure Water

What is Drinking Water RO System?

Drinking water ro system is raw water by reverse osmosis system precision filter, granular activated carbon filter, activated carbon filter, compression, and then through the pressure of the pump, the use of reverse osmosis membrane pore size 1/10000 microns to make relatively high concentrations of water into the low concentration of water, and industrial pollutants, heavy metals, bacteria, viruses and other impurities mixed in the water of a large number of sufficient isolation, In order to achieve the physical and chemical indicators of drinking water and sanitation standards, pure water is the best choice for the body to replenish water quality.

Technical specifications of Drinking Water RO System

Model

JFRO-500L

Host Size

800x600x1600mm (can be customized)

Power

1.5KW

Power Supply

220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized

Operating Pressure

0.8-1.2MPa

Recovery Rate

50%

Designed Water Inlet

1000L/h

Outlet Flow

500L/h

Desalination Rate

≥99.5%

RO Frame

SUS304

Membrane Size

4040

Membrane Elements

DOW /Hydranautics/Troy/ Vontron (Optional)

Number of Membranes

2

Raw Water Pump

CNP/NYP/GRUNDFOS (Optional)

Raw Water Pump

CNP/NYP/GRUNDFOS (Optional)

Tank Material

SS/FRP (Optional)

Control Valve

Manual/Automatic

Control Valve Brand

FLECK/RUNXIN

Membrane Housing

SS/FRP (Optional)

Pipe Material

U-PVC, Stainless steel (Optional)

The working process of Drinking Water RO System


1. Preprocessing
2. Reverse osmosis
3. Post-processing
4. Cleaning
5. Electrical control

500LPH Drinking Water RO System FRP Manual Control For Pure Water

The separation capacity of drinking water ro system membrane technology?


Reverse osmosis is currently a relatively accurate liquid filtration technology. RO reverse osmosis membrane can retain inorganic molecules such as dissolved salts and organic compounds with molecular weight greater than 100. On the other hand, water molecules can freely pass through the RO membrane, and the removal rate of typical soluble salts is high.

RO system failure analysis table:

possible reason possible location pressure drop Product water flow salt permeability
Metal oxide The first section usually increases decline usually increases
colloid fouling The first section usually increases decline usually increases
fouling The last section increases decline increases

Biofouling

any section usually decline increases Increase

organic fouling

all sections normal decline usually increases

Oxidizing agent (eg: Cl2)

The first part is the most serious usually decline increases Increase
Surface wear (carbon particles,sludge) The first part is the most serious decline increases Increase

Cracks in O-rings or glued

random usually decline usually decline Increase
The recovery rate is too high all parts decline usually decline Increase

500LPH Drinking Water RO System FRP Manual Control For Pure Water

500LPH Drinking Water RO System FRP Manual Control For Pure Water

500LPH Drinking Water RO System FRP Manual Control For Pure Water

500LPH Drinking Water RO System FRP Manual Control For Pure Water

500LPH Drinking Water RO System FRP Manual Control For Pure Water

500LPH Drinking Water RO System FRP Manual Control For Pure Water

500LPH Drinking Water RO System FRP Manual Control For Pure Water

500LPH Drinking Water RO System FRP Manual Control For Pure Water

500LPH Drinking Water RO System FRP Manual Control For Pure Water

FAQ:

1. What is the membrane material of drinking water reverse osmosis system?

Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis

Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.

2. What is the material of mechanical filter?

Carbon steel, stainless steel, fiberglass

3, multi-way control valve according to the control mode of those?

Manual control valve, automatic control valve

Multi - way control valve is divided into: filter valve and softening valve

Automatic control valve is divided into: time type and flow type.

Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.

Inquiry Cart 0