Jufu Water Technology Co., Ltd
Province/State:Shaanxi
Country/Region:china
Contact Person:MsChloe Cheung
Contact Now

100TPH RO Water Treatment System For Landfill Leachate Treatment System

Ask Latest Price
Video Channel
Brand Name :Jufu
Model Number :JFRO-100T
Certification :ISO9001
Place of Origin :China
MOQ :1 unit
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :2-4 weeks
Packaging Details :Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping.
RO frame :SUS304/Carbon Steel (optional)
Warranty :1 Year
Capacity :100TPH
Power :110KW
Recovery :75%
Desalination rate :≥99.5%
Membrane size :8040
Nbr of Membranes :108
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

100TPH RO Water Treatment System For Landfill Leachate Treatment System

Reverse osmosis (RO) systems are common water purification system devices that use partially permeable membranes to separate ions, unwanted molecules, larger particles and colloid, organic impurities, and heavy metal ions from drinking water. RO water treatment system remove a wide range of dissolved and suspended chemicals and biological substances (mainly bacteria) from water, as well as asbestos, a variety of taste, color and odor producing chemicals, particulates, total dissolved solids, turbidity and radium for industrial processes and drinking water production.


How does RO Water Treatment System Works


The reverse osmosis system is an important part of the water treatment system and is widely used in the preparation of purified water and drinking water. When the RO membrane is on one side of the selective membrane, by applying pressure to the solution, the RO membrane removes many types of macromolecules and ions from the solution. The result is that solutes such as iron, viruses, bacteria and solids are retained on the pressurized side of the membrane, while pure solvent is allowed to pass through the other side of the membrane.

Technical Specifications of
RO Water Treatment System

Model JFRO-100T
Host Size 7200x2000x2200mm (can be customized)
Power 110KW
Power Supply 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure 1.2~1.5MPa
Recovery Rate 75%
Designed Water Inlet 135t/h
Outlet Flow 100t/h
Desalination Rate ≥99.5%
RO Frame SUS304/Carbon Steel (Optional)
Membrane Size 8040
Membrane Elements DOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes 108
Raw Water Pump CNP/NYP/GRUNDFOS (Optional)
High Pressure Pump CNP/NYP/GRUNDFOS (Optional)
Tank Material SS/FRP(Optional)
Control Valve Manual/Automatic
Control Valve Brand FLECK/RUNXIN
Membrane Housing FRP
Number of Membrane housing 18
Pipe Material U-PVC/ Stainless steel (Optional)

RO Water Treatment System Process Flow:


Source water tank → source water booster pump → multi-media filter → active carbon filter → resin softening device → precision filter → first RO reverse osmosis pure water system → second RO reverse osmosis pure water system → water-gas mixer → ozone sterilizer → stainless steel pure water tank → automatic filling line

100TPH RO Water Treatment System For Landfill Leachate Treatment System

Features and Benefits of RO Water Treatment System


1. The system can produce water automatically and continuously.
2. No need for chemical regeneration, easy to operate and maintain.
3. The core components of the reverse osmosis system are the CNP pump and the Vontron reverse osmosis membrane.
4. The pure water tank is automatically opened when the water level is low, and the original water tank is automatically closed when the water level is high.
5. The system will automatically flush the reverse osmosis membrane for about 90s, reducing the membrane fouling speed.
6. Water shortage protection and low pressure protection switch of water pump.
7. The conductivity monitor will continuously detect the water quality online and display the data.
8. The whole system adopts water flow meter, pressure gauge, solenoid valve, regulating control valve and control panel.
9. The reverse osmosis controller makes the whole reverse osmosis system run automatically.
10. Easy to control and maintain.

Application fields of RO Water Treatment System


1. Purification of purified water, distilled water, food and beverage water.
2. Preparation of pure water and ultrapure water in electronics, medicine, food and other industries.
3. Process engineering for separation, concentration and liquid decolorization in light textile, chemical, food and other industries.
4. Desalination of sea water and brackish water

Photos of RO Water Treatment System

100TPH RO Water Treatment System For Landfill Leachate Treatment System

100TPH RO Water Treatment System For Landfill Leachate Treatment System

100TPH RO Water Treatment System For Landfill Leachate Treatment System

100TPH RO Water Treatment System For Landfill Leachate Treatment System

100TPH RO Water Treatment System For Landfill Leachate Treatment System

100TPH RO Water Treatment System For Landfill Leachate Treatment System

100TPH RO Water Treatment System For Landfill Leachate Treatment System

FAQ:

1. What are the inlet water quality requirements for ro water treatment system membrane components?

Items

NTU SDI Residual chlorine(mg/L) Fe2+(mg/L) TOC(mg/L)
Limits ≤1 ≤5 ≤4 ≤3

2. What is the material of ro water treatment system membrane?

Acetate membrane (CA) : mainly because of its resistance to chlorine, so it is still durable. But its suitable pH range is small, easy hydrolysis

Aromatic polyamide membrane (PA) : water almost can not have chlorine, only through a variety of pretreatment chlorine.

3. RO water treatment system configuration:

First-stage multi-stage process: if the recovery rate is not achieved in the first stage (50-65% in the first stage and 65-75% in the second stage), the multi-stage tandem filtration can be used. The effective cross-sectional area of each segment decreases. 2:2 and 2:3 and 4:2:1

Multi-stage process: when the first stage process cannot meet the effluent quality requirements (the first stage is generally ≤20μs/cm), the product water of the first stage process is sent to another reverse osmosis unit.

The arrangement of membrane components can be divided into series and parallel.